Let's talk

Sacrificial anode

Data points

Status Values

Value Type
Quantity
Instance quantity (qty)
How many physical units this instance represents. Used by the inventory engine for allocation and availability calculations.
Measure
Anode specifications
Fixing method
The mechanical method by which the anode is secured to the vessel or fitting.
Attribute
Anode depletion status
Anode mass (installed)
The recorded mass of the anode at the time of installation. Forms the baseline for all subsequent depletion calculations.
Measure
Remaining mass
The measured mass of the anode at the time of inspection. Used to calculate depletion percent and material loss.
Measure
Remaining mass %
Remaining mass of an anode expressed as a percentage of original mass.
Measure
Remaining life
Forecast time until the item reaches its replacement threshold.
Measure
Manufacturer Provenance
Lot No.
Lot number of item.
Attribute
Manufacture Date
Date when the equipment or vessel was originally manufactured.
Lifecycle
Serial Number
Unique manufacturer serial number.
Attribute
Item Expiry Date
Date when an item expires and must be renewed or replaced.
Lifecycle
Operational lifecycle events
Installation date
Date the item was installed. Note this may be a different date to the commissioning date.
Lifecycle
Visual Inspection Status
Visual condition
Free text input as the result of visual inspection.
Attribute
Last visual inspection date
Date of last visual inspection.
Lifecycle
Visual inspection interval (time based)
Time based interval between visual inspection.
Measure
Forecast visual inspection date (time based)
Date when the next visual inspection is planned calculated from the last inspection date and time based inspection interval.
Lifecycle
Next Visual Inspection date
Date of next planned visual inspection.
Lifecycle
Acquisition lifecycle events
Purchase date
Date item was purchased.
Lifecycle
Warranty period
Period of the product warranty from purchase date.
Measure
Warranty expiry date (calculated)
Calculated the item's warranty expiry date based on the purchase date and warranty period.
Lifecycle
End of life events
Disposal Date
Date when the item was permanently removed or decommissioned.
Lifecycle
Decommissioning date
Date item was decommissioned.
Lifecycle

Property Values

Value Type
Dimensions - length
Length (L)
Length of item.
Measure
Dimensions - width & gap
Width (W)
Width of item.
Measure
Dimensions - thickness
Thickness
Measure
Dimensions - slot
Slot width
The width of a slot in an item such as an anode.
Measure
Slot length
The length of a slot in an item such as an anode.
Measure
Slot centre gap
Distance of the centres between two slots of an item such as the slots in an anode.
Measure
Anode specifications
Fixing points
The number of bolts, screws, or other fixings securing the item in place.
Measure
Anode material
The primary metal composition of the sacrificial anode.
Attribute
Anode form
The physical shape of the anode body. Determines suitability for specific mounting locations and protection zones.
Attribute
Material compatibility
The fitting material or metals the anode is designed to protect against galvanic corrosion.
Attribute
Water type
The water type in which the vessel operates. Directly determines correct anode material selection and expected depletion rate.
Attribute
Manufacturer Provenance
Part No.
Manufacturer's part number.
Attribute
Regulatory classification
ABYC Standard
American Boat and Yacht (ABYC) reference standard.
Attribute
MIL-DTL
U.S. Military Specification (MIL-DTL).
Attribute
DNV Standard
DNV (formerly Det Norske Veritas) classification society standard.
Attribute
Dimensions - mass & weight
Weight
The weight of an item.
Measure
Performance
Design life span
Expected service life under normal conditions as declared by the manufacturer or derived from standard practice.
Measure
Protection potential
The electrochemical potential measured at the protected metal. The primary ABYC E-2 performance criterion.
Measure
Bonding continuity resistance
The electrical resistance between the anode and the bonding system. ABYC E-2 requires connections of 1 ohm or less for effective cathodic protection.
Measure
Anode electrochemical capacity
Anode electrochemical capacity
Measure
Bonded to system
Identifies if an anode is electrically connected to the vessel's cathodic protection bonding system.
Attribute
Dimensions - diameter & bore
Outer diameter
Outer diameter of an item.
Measure
Bore diameter
Internal diameter of the fitting — critical for flow calculations of water, air or other gases and fluids.
Measure

We Value Your Privacy

We use cookies to enhance your browsing experience, analyze site traffic, and personalize content. By clicking "Accept All", you consent to our use of cookies. Learn more

Cookie Preferences

Essential Cookies

Required for the website to function properly. Cannot be disabled.

Analytics Cookies

Help us understand how visitors interact with our website.

Marketing Cookies

Used to deliver personalized advertisements relevant to you.